Kane 5-Gas Automotive Diagnostic Exhaust Gas Analyzer (With Printer)
Features:
- Tests HC, O2, CO, CO2, NOX and Lambda.
- Readings are LIVE. (except NOx and LAMBDA which are calculated).
- Detect problems too marginal to be detected by an onboard computer or scan tool.
- Interprets the exhaust gases & their interactions.
- Provides a top-down list of suggested problems and solutions in order of probability.
- Reduce diagnostic time, verify repairs are complete, reduce comebacks, and increase overall profitability and customer satisfaction.
- Self-calibrating, no cal-gas required.
- Dyno not required for NOX testing.
- Completely portable.
- Low cost to operate and maintain.
- Operates off internal rechargeable battery.
- Water trap and filter visible.
- Display: Large and easy to read all gases and Lambda on one screen, no scrolling
- Ergonomic Design Keypad: Simple and easy to navigate and use.
- Bluetooth or USB Cable ready: Links analyzer easily to PC to use with KANE LINK.
- Variable Pump Speed: Allows for adjustment of the pump speed, which can then improve battery life
- Optional Hi-Speed Print Capability: Use with the hi-speed printer with rechargeable battery.
- Probe: Equipped with the EP1 Hi-Temperature Probe, with Neoprene tubing and a 350mm insertion depth.
Quickly and easily diagnose vehicle issues through exhaust gas with the Kane 5-Gas Automotive Diagnostic Exhaust Gas Analyzer With Printer. It's great for diagnosing performance, drivability, no code, and catalytic converter issues as well as other problems that most scanners and onboard computers cant. The EGA5 even offers suggestions on how to repair these issues. It's the most comprehensive and complete exhaust gas analyzer on the market!
Technical Specifications:
Parameter |
Resolution |
Accuracy |
Range |
Carbon Monoxide (High Range NDIR) |
0.01 % |
+/- 5 % of reading *1 |
0-10 % |
Oxygen |
0.01 % |
+/- 0.3 % volume *1 |
0-25 % |
Hydrocarbon (NDIR) |
1 ppm |
+/- 5 % of reading *1 +/- 12 ppm volume *1 |
0-5000 ppm Over-range: 10,000 ppm |
Carbon Dioxide (NDIR) |
0.1 % |
+/- 0.3% of reading *1 |
0-20 % |
Nitric Oxide*² (fuel cell) |
1 ppm |
0-1500ppm +/-5% or 25ppm; |
0-5000ppm |
Carbon Monoxide Corrected COK |
0.01% |
Calculated |
0-15% |
Lambda AFR (Petrol) (LPG) |
0.001 00.01 |
|
0.8 – 1.2 11.76 – 17.64 12.48 – 18.72 |
Sensor response Time |
Nominal 20 seconds |
Warm up |
Less than 2 minutes |
Pre-programmed Fuels |
Petrol/Gasoline, LPG Diesel and CNG. |
PC connection |
Via RS 232 port |
Data-Logging |
200 Tests |
Dimensions Weight Handset Probe |
1.2 kg (2.65 pounds) 240mm x 165mm x 65mm (9.45 x 6.5 x 2.56”) Insertion depth 350mm x Diameter 15mm Clip handle to secure to exhaust, 4m long hose Various probes available including high temperature |
Ambient Operating Range |
+5°C to +50°C / 10% to 90% RH non-condensing |
Storage temperature |
Minimum: 0°C Maximum: +45°C |
Battery Charger |
Input: 100-240 V Output: 12 V DC |
Analyzer battery run time |
6+ hours from full charge. |
ANSED Exhaust Gas Diagnostic Software:
- Interprets the exhaust gas analyzer readings in seconds!
- Uses a floating matrix formula for each gas reading, coupled with other diagnostic variables, to enhance the accuracy.
- Several possible solutions, in order of probability, are suggested with the first one the likely cause in 80% of the situations.
- Diagnose no-code drivability & performance issues
- Ensure catalytic converter related repairs are complete
- Print test results reports: pre- and post-repair
- Verify vehicle running at max efficiency after repairs and prevent comebacks
- Easy-to-read PASS/FAIL report.
- Pre-repair reports provide initial gas analysis for review.
- Customer Report offers a “customer friendly analysis” of the exhaust diagnostic test.
- Technician Report details the diagnostic test results and suggested procedures.
- Post-repair report verifies that repairs have been completed and the vehicle is running at maximum efficiency.
- All reports can be printed or saved for future reference.
What's Included?
- KANE-EGA5 5-Gas Analyzer
- EP1 Hi-Temp Probe
- KANE-IRP3 Infra-red Printer
- CU12VDC2A21 AC Charger
- CA10733/4 12V In-Vehicle Charger
- PF2/5 Replacement Filters (pack of 5)
- User Manual & Quick Start Guide
- ANSED Exhaust Gas Diagnostics Software (FREE)
- KANE LINK wireless module
- CL5 USB Cable
- 14102/2 Shoulder Carry Bag
Kane EGA5, EGA1NO, & EGA1HR Product Flyer
Need more info? Please contact us or go to the Ansed Resource Center.
Item Location & Shipping
-Ships from the USA.
-Most orders processed within 24 hours.
-Average transit time is 3 business days.
-We ship with either USPS, UPS or FedEx.
-Want to double check? Just ask! Contact us here.
Questions & Answers
Have a Question?
Be the first to ask a question about this.